The complete system, with the blue cylinder
Cylinder, collectors, differential thermostat and pump station. What each model includes is set out in its description.
A blue hot water cylinder of 150 or 200 litres, triple energy, with two heat exchangers, and 2.5 to 5 m² of selective collectors, with a pre-assembled kit.
Installer or retailer? Log in for trade prices
Forced circulation solar systems are designed for installations with large hot water needs, such as apartment blocks, hospitals, sports facilities and hotels, and also for homes, when the tank cannot sit above the collectors for aesthetic or structural reasons.
The system consists of a blue hot water cylinder of 150 or 200 litres, triple energy, with two heat exchangers, and Mastersol selective solar collectors with a total area of 2.5 to 5 m², depending on the model. It comes with flat-roof frames for the collectors, the Mastersol pre-assembled forced circulation kit (solar pump station), a differential thermostat with sensors, a closed expansion vessel, an automatic filling valve, antifreeze and the connection materials for the collectors, in quantities that match the collectors.
The electric heating element is an option: single-phase 3 kW or three-phase 6, 9 or 12 kW, with or without a thermostat. The differential thermostat compares the collector temperature with the cylinder's and starts the circulator of the pump station when the sun can give heat.
Cylinder, collectors, differential thermostat and pump station. What each model includes is set out in its description.
For each cylinder size there are combinations with a different collector area. Which one suits your needs is something we can work out together.
| Compare the models | BL2150/2.5-BLUE1,459.06 € | BL2150/3-BLUE1,561.93 € | BL2150/4-BLUE1,649.95 € | BL2200/2.5-BLUE1,438.11 € | BL2200/4-BLUE1,628.99 €This model | BL2200/5-BLUE1,737.96 € |
|---|---|---|---|---|---|---|
| Collector area | 2.5 m² | 3 m² | 4 m² | 2.5 m² | 4 m² | 5 m² |
| Tank capacity | 150lt | 150lt | 150lt | 200lt | 200lt | 200lt |
| Actual volume | 138 lt | 138 lt | 138 lt | 183 lt | 183 lt | 183 lt |
| Heat exchangers | 2 | 2 | 2 | 2 | 2 | 2 |
| Heat exchanger surface | upper 0.3 m², lower 0.6 m² | upper 0.3 m², lower 0.6 m² | upper 0.3 m², lower 0.6 m² | upper 0.3 m², lower 0.6 m² | upper 0.3 m², lower 0.6 m² | upper 0.3 m², lower 0.6 m² |
| Tank height | 1240 mm | 1240 mm | 1240 mm | 1240 mm | 1240 mm | 1240 mm |
| Tank diameter | 550 mm | 550 mm | 550 mm | 600 mm | 600 mm | 600 mm |
| Tank insulation | 50mm hard polyurethane, 44 kg/m³ | 50mm hard polyurethane, 44 kg/m³ | 50mm hard polyurethane, 44 kg/m³ | 50mm hard polyurethane, 44 kg/m³ | 50mm hard polyurethane, 44 kg/m³ | 50mm hard polyurethane, 44 kg/m³ |
| Maximum working pressure | 8 bar | 8 bar | 8 bar | 8 bar | 8 bar | 8 bar |
| Tank weight | 71.4 kg | 71.4 kg | 71.4 kg | 72.6 kg | 72.6 kg | 72.6 kg |
| Collector type | Selective, aluminium – titanium | Selective, aluminium – titanium | Selective, aluminium – titanium | Selective, aluminium – titanium | Selective, aluminium – titanium | Selective, aluminium – titanium |
| Collector efficiency | 95% ±2% | 95% ±2% | 95% ±2% | 95% ±2% | 95% ±2% | 95% ±2% |
| Warranty | 7 years boiler, 15 years collectors | 7 years boiler, 15 years collectors | 7 years boiler, 15 years collectors | 7 years boiler, 15 years collectors | 7 years boiler, 15 years collectors | 7 years boiler, 15 years collectors |
Manufacturer's data; for the cylinder they may vary by up to ±5%. Prices include VAT, without the electric heating element.
| Solar collectors | |
|---|---|
| Collector area | 4 m² (2 × 2.0 m²) |
| Collector back | 0.5mm galvanised steel |
| Collector efficiency | 95% ±2% |
| Collector frame | Aluminium, one piece |
| Collector insulation | Double mineral wool 4cm |
| Collector type | Selective, aluminium – titanium |
| Riser grid | Copper Φ22 & Φ8 |
| Cylinder | |
| Tank type | Vertical hot water cylinder |
| Tank capacity | 200lt |
| Actual volume | 183 lt |
| Heat exchangers | 2 |
| Heat exchanger surface | upper 0.3 m², lower 0.6 m² |
| Tank height | 1240 mm |
| Tank diameter | 600 mm |
| Tank weight | 72.6 kg |
| Tank insulation | 50mm hard polyurethane, 44 kg/m³ |
| Maximum working pressure | 8 bar |
| Maximum test pressure | 10 bar |
| Warranty | |
| Warranty | 7 years boiler, 15 years collectors |
| Ranges | |
| Litres | 200 lt (4-5 users) |
The cylinder's magnesium anode is a consumable and is not covered.
Warranty form (PDF, in Greek) →A partner installer does the site visit, the connection and the first start-up. Ask for a quote together with the product.
Contact us →Our engineers calculate your home's heat loss and confirm the choice. The first assessment is free.
Contact us →Our technicians answer every question, from choosing to installing.
2610 334 389 info@climaventis.grWhen hot water needs are large, e.g. in apartment blocks, hotels or sports facilities, or when the tank cannot sit above the collectors, for aesthetic or structural reasons.
The cylinder, the Mastersol selective collectors with flat-roof frames, the Mastersol pre-assembled kit (solar pump station), a differential thermostat with sensors, a closed expansion vessel, an automatic filling valve, antifreeze and the connection materials for the collectors. The electric heating element is an option.
Single-phase 3 kW or three-phase 6, 9 or 12 kW, with or without a thermostat. Which one fits depends on the power supply and the installation; ask us if you are not sure. The system is also sold without a heating element.
The flat-roof frames are included. For a tiled roof, contact us.
It compares the collector temperature with the cylinder's and starts the circulator when the sun can give heat.
7 years on the cylinder and 15 years on the collectors.
Collect it from our shop in Patras, or we send it by carrier. The shipping cost shows in the cart; if it does not show for your area or size, call us for the delivery cost. A plumber installs it; we can suggest a partner in your area.